Alken-Murray logo header

Dosage for Alken Clear-Flo 7110 - Regular Strength

  < 50 ppm of Ammonia

 > 50 ppm of Ammonia

Product volume in this table is in gallons

 MGD
 Day 1  Day 2

 Days 3 - 7

 Days 8 - 14

 Days 15 +
 

Day 1 

 Day 2

 Days 3 - 7 

 Days 8 - 14

 Days 15 +

 0.25

 8

 4

 3

 2

 0.8
 

 12

 8

 3

 2

 0.8

 0.50

 16

 8

 5

 2.4

 0.9
 

 24

 12

 7

 2.7

 1

 0.75

 24

 12

 7

 2.7

 1
 

 33

 16

 10

 3.1

 1.3

 1.00

 33

 16

 10

 3.1

 1.3
 

 44

 24

12 

 4.7

 1.9

 1.50

 44

 18

 11

 3.5

 1.4
 

 56

 28

 14

 5.5

 2.2

 2.00

 60

 20

 13

 4

 1.6
 

 68

 32

 15

 7.4

 3

 3.00

 88

 28

 14

 5.9

 2.4
 

 112

 44

 16

 9.3

 3.7

 4.00

 132

 32

 15

 7.8

 3.2
 

 156

 48

 20

 12

 4.8

 5.00

 176

 44

 16

 11

 4.4
 

 200

 72

 25

 15

 6

Dosage for Alken Clear-Flo 7110 - 50x

  < 50 ppm of Ammonia

 > 50 ppm of Ammonia

Product volume in this table is in ounces, unless specified in gallons

 MGD
 Day 1  Day 2

 Days 3 - 7

 Days 8 - 14

 Days 15 +
 

Day 1 

 Day 2

 Days 3 - 7 

 Days 8 - 14

 Days 15 +

 0.25

 21

10

 7

 5

 2
 

 31

 21

 7

 5

 2

 0.50

42

 21

 13

 6

 2.5
 

 62.5

 31.5

19

 7

 3

 0.75

 62.5

 31.5

 19

 7

3
 

 83.5

 42

26

 8

 3.2

 1.00

 83

 42

 26

 8

 3.2
 

 113

 62.5

30 

 12

 4.8

 1.50

 113

 52.5

 30

 10

 4
 

 1.1 gal

72

 35

 14

 5.6

 2.00

 1.2 gal

63

 33

 12

 4.8
 

 1.5 gal

 82

 39

 19

 8

 3.00

 2 gal

 72

 36

 15

 6
 

 2.5 gal

 113

42

 24

 10

 4.00

 3 gal

 84

 38

 20

8
 

3.5 gal

 123

52

 30

12

 5.00

3.5 gal

113

40

27

11
 

4 gal.

1.5 gal.

65

 38

 15

Most systems will respond within 14 days of treatment, typically within 3 to 6 days. If the program fails to produce significant results within 2 weeks, contact Valerie or Claudia.
Monitoring of the treated system should minimally include ammonia, nitrite, nitrate, dissolved oxygen and pH. Additional parameters recommended for monitoring include TKN, total alkalinity, and effluent BOD5. This data is indispensible for troubleshooting and qualifying applications. Be sure to maintain sufficient alkalinity to prevent pH drop below 7.0.
The data included in these tables are based on test information obtained by Alken-Murray Corporation. The data are believed to be reliable, but do not imply warranty or performance guarantee.We recommend that the user determine performance by testing on his own installation with our bench test procedure. ALKEN CLEAR-FLO is a registered trademark of Alken-Murray Corporation.

E-mail: clearflo@alken-murray.com

Alken-Murray banner link to homepage