ALKEN CLEAR-FLO® 7014
Effective Date: 01/18/2007
Manufacturer's Name: Alken-Murray Corporation | |
Manufacturer's Address: P.O. Box 400, New Hyde Park, New York 11040 | |
T: 540-636-1236 Fax: 540-636-1770 | |
E-mail: msds@alken-murray.com | |
Manufacturer's Cage Code: 2A384 |
NFPA Hazard Ratings: 0=Minimal, 1=Slight, 2=Moderate, 3=Serious, 4=Severe |
Health=1 | Fire=1 | Reactivity=1 |
Synonyms: | none |
CAS Number: | Not applicable to mixtures |
Chemical Formula: | mixture |
Formula ID Codes: | 7014 |
Chemical Name | CAS Number | OSHA PEL | ACGIH TLV | % Weight |
Wheat bran substrate | 116469-86-4 | NDA | NDA | 56 - 71 |
Water | 7732-18-5 | NDA | NDA | 10 - 15 |
Viable bacterial cultures | NA | NDA | NDA | 1 |
Ammonium chloride | 12125-02-9 | NDA | NDA | 10 - 15 |
Disodium phosphate (DSP) | 7758-79-4 | 15 mg/M3 | 10 mg/M3 | 10 - 15 |
Cellulase enzyme | 9012-54-8 | NDA | NDA | 1 - 2 |
Xylanase enzyme | 37278-89-0 | NDA | NDA | < 1 |
Emergency Overview: Organisms used are non-pathogenic, but can cause infection when in contact with open wounds. These organisms are susceptible to many commonly used antibiotics. Potential Health Effects: |
|
|
Flash Point: > 93 degrees C (>199.40 deg. F) Flammability Limits: NA Autoignition temp: NA Fire Extinguishing Media: Water spray, carbon dioxide, dry chemical Special Fire-Fighting Information: None Unusual Fire and Explosion Hazards: None |
Soil spill: Dig a pit, pond, or lagoon holding area to contain liquid or solid material. Cover solids with a plastic sheet to prevent dissolving in rain or firefighting water. Water spill: Add suitable agent to neutralize spilled material to pH 7 then place into a chemical waste container. Wear approved respirator for nuisance dust during cleanup. |
Store in cool dry place. Keep container closed when not in use. Avoid storage of product above 110 degrees F and keep from freezing. Keep out of direct sunlight. |
|
|
|
|
Environmental Fate: No information found Environmental Toxicity: NA |
RCRA Hazard Class (if discarded): Neat, unused product is not considered a hazardous waste, according to RCRA regulations 40 CFR 261. For proper disposal of used materials, an assessment must be completed to determine the proper waste management options permissible under applicable rules, regulations and/or laws governing client's location. Wash containers down with water and disinfect with a 1% sodium hypochlorite solution, triple rinse and dispose of rinse water to sewer. Then remove or deface product label to avoid confusion if pail or drum is later refilled. Clean, empty containers should be recycled or disposed of through an approved waste management facility. |
|
..................................Section 302/304 Extremely Hazardous Substances: None ..................................Section 311 Hazard Categorization: Acute, chronic ..................................Section 313 Toxic Chemicals: None
|
16. Other Information Reason for Revision: Formula revision, fungal cultures replaced with enzymes Alken-Murray Corporation provides the information contained herein in good faith, in compliance with the Occupational Safety and Health Act of 1970, but makes no representation as to its comprehensiveness or accuracy. This document is intended only as a guide to the appropriate precautionary handling of the material by a properly trained person using this product. Alken-Murray warrants that this product is of merchantable quality. The implied warranty of fitness for a particular purpose is limited to the extent the products are used for the purpose or uses described on the product's label or in any written instructions or materials distributed to the buyer by Alken-Murray and is hereby disclaimed should buyer use the products in a manner inconsistent with this uses or purposes described therein. In no event shall Alken-Murray be liable for any consequential, exemplary, or incidental damages incurred by buyer even if it has been advised of the possibility of such damages. |